Dual
use systems are designed to accommodate
the needs to power different trailer
types, each with a separate system
pressure requirement. An example would
be where an operator may need to power a
dump trailer which requires 2000 psi max
pressure, but may also be required to
power a walking floor or lowboy trailer,
which has a requirement of 2500 to 3000
psi max working pressure.
Components:
A
Chelsea (Parker) 8-bolt Air Operated
Power Take-Off with a direct mount pump
option.
A high
pressure bushing type hydraulic pump is a
necessary component in this type system, due to
the demands of operating at the
higher pressures of many of today's hydraulic
trailer systems. The pump is rated at
31.50 GPM at 1200 rpm (6.38 C.I.R.),
with a pressure rating up to 3500 psi
maximum. Direct mounted to the PTO, it
eliminates the need for a driveline.
Our
Commercial Intertech (Parker) Dual Use
Control Valve includes an
adjustable main relief, preset at 2500
psi, which controls pressure to the
power beyond port (used to power the
higher pressure trailer system). An
integrated port relief preset to 2000
psi controls pressure from the work port
(used to power the standard pressure
system, such as a dump hoist cylinder),
thereby offering protection for
components rated for lower pressure
settings. Our Dual Use control valve is
available for Air or Manual operation.
A
Parker Inline Return filter assembly
with flow capacity of 50 gallons and a
10 micron element rating is recommended.
A
Hydraulic Reservoir with a minimum
capacity of 50 gallons is recommended
Reservoir should also have an integrated
suction strainer and a return line port
below the oil level, as well as an
internal baffle.
|