This
Three Line Dump System utilizes an
integrated hydraulic pump and control
valve. The most common use for this
system is to power a dump/lead trailer.
The third line is for a more continuous
duty, where the PTO may be engaged for
more than 5 minutes at any time. It
allows (with valve in neutral) the pump
the ability to use the entire reservoir
oil capacity for cooling. The third line
also accommodates the
inclusion of a filter assembly in the
system, assuring long component life.
Components:
A
Chelsea (Parker) 8-bolt Air Operated
Power Take-Off with a direct mount pump
option.
A
Commercial Intertech (Parker) hydraulic
Dump Pump, a pump and control valve
integrated into one unit, rated at 30 GPM at 1200 rpm (6.38
C.I.R.), with a pressure rating up to
2000 psi continuous duty. Direct mounted
to the PTO, it eliminates the need for a
driveline. Air operated valve (manual
available).
*A three-line sleeve must be installed
in the inlet port for three line
functionality.
A
Parker Inline Return filter assembly
with flow capacity of 50 gallons and a
10 micron element rating is recommended.
A
Hydraulic Reservoir with a minimum
capacity of 50 gallons is recommended
Reservoir should also have an integrated
suction strainer and a return line port
below the oil level, as well as an
internal baffle.
|